The GL 2000 Control PAK from Balboa replaces the HS200 PAK in the Tiarra, Lexxus, Stratus, Solaris, Millennium and Omni.  The new plastic casing meets new CE standards.  In addition, the system will allow single, two and three phase power connections.  Along with the new PAK, the control boards have also been modernized with the introduction of The ML400 in the Tiarra and Lexxus and the ML700 in the Stratus, Solaris, Millennium and Omni. Single pump models (Tiarra and Lexxus) will now run on as little as 16 Amps.
   

Resources

There are two sets of switches on the GL 2000 board.  One with 12 and one with 6.  This will allow the spas to conserve power by disabling the heater when pumps are set on high mode.  Because the pumps generate a considerable amount of heat as a function of friction, The occupant should not notice any drop in heat when high pumps are engaged. User Card

Spec. Sheets

ML400 Millennium 50 Cycle Export
ML700 Omni 50 Cycle Export

12 Bank Set

6 Bank Switch Settings

 

Amps Used Per Spa (2.5kw Heater)

1 Down 1 UP    Model Factory
Configuration
Low Power
Configuration
2 Down 2 Down   Tiara

Lexxus

Stratus

Solaris

Millennium

Omni

Stamina &
Endurance

Z Series

Sterling

32 AMP

32 AMP

48 AMP

48 AMP

48 AMP

48 AMP

16  AMP


48 AMP

48 AMP

16AMP

16 AMP

32 AMP (dual 16)

32 AMP (dual 16)

32 AMP (dual 16)

32 AMP (dual 16)

13 AMP
(plug'n play)

32 AMP (dual 16)

32 AMP (dual 16)

3 Down 3 UP
4 UP 4 Down
5 UP 5 Down
6 Down* 6 Down
7 Down *After changing settings power up the spa for 2 minutes.  Power off and set switch 6 (in the bank of 12) to the UP position.  This will clear the memory. Shut spa down and Turn 6 to the DOWN position. The spa is now configured for 24 hour circulation in reduced power mode.
8 UP
9 UP
10 Down
11 Down
12 Down
 Home   |  Models  |  Ex-Im Financing  |  Dealer Sign-Up  |  e-mail us  |  Dealers  |   Contact Us